info@one-solar.net

350W-1200KW 12V-24V Wall mounting Low Frequency Pure Sine Wave Inverter With AC Charger - 【HI Series】

  •  12v 220v 10000w solar power inverter with AC charger
  •  12v 220v 10000w solar power inverter with AC charger
 12v 220v 10000w solar power inverter with AC charger 12v 220v 10000w solar power inverter with AC charger

12v 220v 10000w solar power inverter with AC charger

  • LCD Display
  • Transformer 3 times surge power
  • Transfer efficiency>87%
  • Pure sine wave Inverter
  • Product description: Low frequency solar inverter / pure sine wave solar inverter / high transfer efficiency up to 87%
  • INQUIRY


1. Toroidal transformer: higher efficiency87%

2. Built-in automatic AC charger and automatic AC mains switcher.Switch time 8ms.

3. 3 times surge power

4. With built-in AVR stabilizer AVR output voltage stabilizer:3 stages continuously stabilizing,

140-275VAC input always keep 220 VAC output.

Continuous sable pure sine wave output.

5. Double output wave filter: make pure sine wave output more pure

6. 64-bits DSP intelligent control chipset,high speed process and control more function and intelligent.

7. LCD display with multi-function

850Hz/60Hz automatic recognition



Model HI-351 HI-501 HI-601 HI-701 HI-102 HI-122
Rated Power 350W 500W 600W 700W 1KW 1.2KW
Peak Power 1050W 1500W 1800W 2100W 3KW 3.6KW
Nominal battery voltage 12VDC 12VDC/24VDC
Input DC input range 10.5-15VDC (12V) / 21-30VDC (24V)
AC Mains input range (220/230/240VAC) 140-275VAC
AC input frequency 50Hz: 45-65Hz / 60Hz: 55-65Hz (50Hz/60Hz automatic recognition)
Protection Low battery alarm ≤10.5VDC (12V) / ≤21VDC (24V)alarm
Low battery protection ≤10VDC (12V) / ≤20VDC (24V)  automatic shutdown
High battery alarm ≥15VDC (12V) / ≥30VDC (24V) alarm
High battery protection ≥17VDC (12V) / ≥34VDC (24V) automatic shutdown
Over load protection 110% more than rated capacity, automatic shutdown
High temperature Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown
Short circuit protection Automatic shutdown
Output Transfer efficiency ≥87%
Output voltage (DC battery mode) 220/230/240VAC±2%
Output frequency (DC battery mode) 60/50Hz±1%
Output wave form Pure sine wave
Output voltage (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer)
AVR output stablizer AC mains<140VAC±5% swtich to DC battery mode, AC mains>150VAC ±5% return to AC mains mode;
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode;
The above is for output 220V system reference, 230V/240V output just multiply by percentage
Output frequency (AC mains mode) automatic tracing from AC input
Other Transfer time Bult- in AC bypass replay (≤8ms)
Display LCD Display with function buttons
Cooling system Intelligent cooling fan control system
≤42℃ slow fan, ≥45℃ fast fan
AC Charger AC charging Voltage 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)
AC charging current Steady 15A
AC over charge protection Battery ≧16V (12V) ≧32V (24V), stop charging after 60s alarm
Working mode
(Optional)
01 AC mains priority
Always use AC mains as priority input to provide AC output and automatically charge the battery,
only stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off
02 Energy saving
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on
03 DC battery priority
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts DC to
AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC output and
automatically start charging the battery (for 24V system, multiply by 2 accordingly)
Comnunication RS-232/USB/SNMP(additional option)
Environment Temperature -20~+75℃
Humidity <95%
Appearance Product size (mm) 280*275*120mm
Packing size (mm) 345*315*187mm
Net Weight (kg) 7.5kg 8.1kg 8.3kg 9.0kg 9.2kg 9.5kg
Gross Weight (kg) 8.0kg 8.6kg 8.8kg 9.5kg 9.7kg

10.0kg

*Product specifications are subject to change without further notice


Model HI-351 HI-501 HI-601 HI-701 HI-102 HI-122
Rated Power 350W 500W 600W 700W 1KW 1.2KW
Peak Power 1050W 1500W 1800W 2100W 3KW 3.6KW
Nominal battery voltage 12VDC 12VDC/24VDC
Input DC input range 10.5-15VDC (12V) / 21-30VDC (24V)
AC Mains input range 70-150VAC (110/120/130VAC)
AC input frequency 50Hz: 45-65Hz / 60Hz: 55-65Hz (50Hz/60Hz automatic recognition)
Protection Low battery alarm ≤10.5VDC (12V) / ≤21VDC (24V)alarm
Low battery protection ≤10VDC (12V) / ≤20VDC (24V) automatic shutdown
High battery alarm ≥15VDC (12V) / ≥30VDC (24V) alarm
High battery protection ≥17VDC (12V) / ≥34VDC (24V) automatic shutdown
Over load protection 110% more than rated capacity, automatic shutdown
High temperature Built-in temperature real time sensor, ≥85 alarm, ≥90 automatic shutdown
Short circuit protection Automatic shutdown
Output Transfer efficiency ≥87%
Output voltage (DC battery mode) 110/120/130VAC±2%
Output frequency (DC battery mode) 60/50Hz±1%
Output wave form Pure sine wave
Output voltage (AC mains mode) stable 110/120/130VAC±10% output (built-in AVR stablizer)
AVR output stablizer AC mains<80VAC±5% swtich to DC battery mode, AC mains>90VAC ±5% return to AC mains mode;
AC mains>135VAC±5% swtich to DC battery mode, AC mains<130VAC ±5% return to AC mains mode;
The above is for output 110V system reference, 120V/130V output just multiply by percentage
Output frequency (AC mains mode) automatic tracing from AC input
Other Transfer time Bult- in AC bypass replay (≤8ms)
Display LCD Display with function buttons
Cooling system Intelligent cooling fan control system
≤42 slow fan, ≥45 fast fan
AC Charger AC charging Voltage 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)
AC charging current Steady 15A
AC over charge protection Battery 16V (12V) 32V (24V), stop charging after 60s alarm
Working mode
(Optional)
01 AC mains priority
Always use AC mains as priority input to provide AC output and automatically charge the battery,
only stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off
02 Energy saving
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on
03 DC battery priority
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts DC to
AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC output and
automatically start charging the battery (for 24Vsystem, multiply by 2accordingly)
Comnunication RS-232/USB/SNMP(additional option)
Environment Temperature -20~+75
Humidity 95%
Appearance Product size (mm) 280*275*120mm
Packing size (mm) 345*315*187mm
Net Weight (kg) 7.5kg 8.1kg 8.3kg 9.0kg 9.2kg 9.5kg
Gross Weight (kg) 8.0kg 8.6kg 8.8kg 9.5kg 9.7kg 10.0kg
*Product specifications are subject to change without further notice



Scan the qr codeClose